Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Diagnostics (Basel) ; 12(10)2022 Oct 07.
Article in English | MEDLINE | ID: covidwho-2065755

ABSTRACT

This study evaluated the performances of immunoassays (LFIA and ELISA) designed for SARS-CoV-2 Antigen (Ag)-detection in nasopharyngeal (NP) and serum samples in comparison to RT-PCR. NP samples from patients with respiratory symptoms (183 RT-PCR-positive and 74 RT-PCR-negative samples) were collected from March to April and November to December 2020. Seroconversion and antigen dynamics were assessed by symptom onset and day of RT-PCR diagnosis. Serum samples from 87 COVID-19 patients were used to investigate the added value of Ag quantification, at diagnosis and during follow-up. The sensitivity of COVID-VIRO-LFIA on samples with Ct ≤ 33, considered as the contagious threshold, was 86% on NPs (CI 95%: 79-90.5) and 76% on serum samples (CI 95%: 59.4-88), with a specificity of 100%. Serum N-Ag was detected during active infection as early as day two from symptom onset, with a diagnostic sensitivity of 81.5%. Within one week of symptom onset, diagnostic sensitivity and specificity reached 90.9% (95% CI, 85.1%-94.6%) and 98.3% (95% CI, 91.1%-99.9%), respectively. Serum N-Ag concentration closely correlated with disease severity. Longitudinal analysis revealed the simultaneous increase of antibodies and decrease of N-Ag. Sensitivities of COVID-VIRO-LFIA and COV-QUANTO-ELISA tests on NP and serum samples were close to 80%. They are suitable COVID-19-laboratory diagnostic tests, particularly when blood samples are available, thus reducing the requirement for NP sampling, and subsequent PCR analysis. ELISA titers may help to identify patients at risk of poor outcomes.

2.
Pathogens ; 10(11)2021 Nov 04.
Article in English | MEDLINE | ID: covidwho-1502481

ABSTRACT

Infections caused by extended-spectrum ß-lactamase-producing Klebsiella pneumoniae (ESBL-KP) are constantly rising worldwide and are often reported as causative agent of outbreaks in intensive care units (ICUs). During the first wave of the COVID-19 pandemic, bacterial cross-transmission was thought unlikely to occur due to the reinforcement of hygiene measures and prevention control. However, we report here an ESBL-producing K. pneumoniae (ST394) isolate responsible for a nosocomial outbreak in an ICU dedicated to COVID-19 patients.

3.
JAMA ; 325(15): 1525-1534, 2021 04 20.
Article in English | MEDLINE | ID: covidwho-1222575

ABSTRACT

Importance: Little is known about long-term sequelae of COVID-19. Objective: To describe the consequences at 4 months in patients hospitalized for COVID-19. Design, Setting, and Participants: In a prospective uncontrolled cohort study, survivors of COVID-19 who had been hospitalized in a university hospital in France between March 1 and May 29, 2020, underwent a telephone assessment 4 months after discharge, between July 15 and September 18, 2020. Patients with relevant symptoms and all patients hospitalized in an intensive care unit (ICU) were invited for further assessment at an ambulatory care visit. Exposures: Survival of hospitalization for COVID-19. Main Outcomes and Measures: Respiratory, cognitive, and functional symptoms were assessed by telephone with the Q3PC cognitive screening questionnaire and a checklist of symptoms. At the ambulatory care visit, patients underwent pulmonary function tests, lung computed tomographic scan, psychometric and cognitive tests (including the 36-Item Short-Form Health Survey and 20-item Multidimensional Fatigue Inventory), and, for patients who had been hospitalized in the ICU or reported ongoing symptoms, echocardiography. Results: Among 834 eligible patients, 478 were evaluated by telephone (mean age, 61 years [SD, 16 years]; 201 men, 277 women). During the telephone interview, 244 patients (51%) declared at least 1 symptom that did not exist before COVID-19: fatigue in 31%, cognitive symptoms in 21%, and new-onset dyspnea in 16%. There was further evaluation in 177 patients (37%), including 97 of 142 former ICU patients. The median 20-item Multidimensional Fatigue Inventory score (n = 130) was 4.5 (interquartile range, 3.0-5.0) for reduced motivation and 3.7 (interquartile range, 3.0-4.5) for mental fatigue (possible range, 1 [best] to 5 [worst]). The median 36-Item Short-Form Health Survey score (n = 145) was 25 (interquartile range, 25.0-75.0) for the subscale "role limited owing to physical problems" (possible range, 0 [best] to 100 [worst]). Computed tomographic lung-scan abnormalities were found in 108 of 171 patients (63%), mainly subtle ground-glass opacities. Fibrotic lesions were observed in 33 of 171 patients (19%), involving less than 25% of parenchyma in all but 1 patient. Fibrotic lesions were observed in 19 of 49 survivors (39%) with acute respiratory distress syndrome. Among 94 former ICU patients, anxiety, depression, and posttraumatic symptoms were observed in 23%, 18%, and 7%, respectively. The left ventricular ejection fraction was less than 50% in 8 of 83 ICU patients (10%). New-onset chronic kidney disease was observed in 2 ICU patients. Serology was positive in 172 of 177 outpatients (97%). Conclusions and Relevance: Four months after hospitalization for COVID-19, a cohort of patients frequently reported symptoms not previously present, and lung-scan abnormalities were common among those who were tested. These findings are limited by the absence of a control group and of pre-COVID assessments in this cohort. Further research is needed to understand longer-term outcomes and whether these findings reflect associations with the disease.


Subject(s)
COVID-19/complications , Hospitalization , Lung Diseases/etiology , Lung/pathology , Aged , Anxiety/etiology , COVID-19/psychology , Cognition Disorders/etiology , Cohort Studies , Depression/etiology , Dyspnea/etiology , Fatigue/etiology , Female , Follow-Up Studies , Humans , Lung/diagnostic imaging , Lung Diseases/diagnostic imaging , Lung Diseases/pathology , Male , Middle Aged , Tomography, X-Ray Computed
4.
Eur J Clin Microbiol Infect Dis ; 40(10): 2235-2241, 2021 Oct.
Article in English | MEDLINE | ID: covidwho-1156953

ABSTRACT

We report evaluation of 30 assays' (17 rapid tests (RDTs) and 13 automated/manual ELISA/CLIA assay (IAs)) clinical performances with 2594 sera collected from symptomatic patients with positive SARS-CoV-2 rRT-PCR on a respiratory sample, and 1996 pre-epidemic serum samples expected to be negative. Only 4 RDT and 3 IAs fitted both specificity (> 98%) and sensitivity (> 90%) criteria according to French recommendations. Serology may offer valuable information during COVID-19 pandemic, but inconsistent performances observed among the 30 commercial assays evaluated, which underlines the importance of independent evaluation before clinical implementation.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing/methods , COVID-19/blood , Immunoassay/methods , SARS-CoV-2/immunology , COVID-19/virology , Humans , Immunoassay/economics , Immunoglobulin M/blood , Reagent Kits, Diagnostic , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , Sensitivity and Specificity
5.
Proc Natl Acad Sci U S A ; 118(12)2021 03 23.
Article in English | MEDLINE | ID: covidwho-1118848

ABSTRACT

Serological rapid diagnostic tests (RDTs) are widely used across pathologies, often providing users a simple, binary result (positive or negative) in as little as 5 to 20 min. Since the beginning of the COVID-19 pandemic, new RDTs for identifying SARS-CoV-2 have rapidly proliferated. However, these seemingly easy-to-read tests can be highly subjective, and interpretations of the visible "bands" of color that appear (or not) in a test window may vary between users, test models, and brands. We developed and evaluated the accuracy/performance of a smartphone application (xRCovid) that uses machine learning to classify SARS-CoV-2 serological RDT results and reduce reading ambiguities. Across 11 COVID-19 RDT models, the app yielded 99.3% precision compared to reading by eye. Using the app replaces the uncertainty from visual RDT interpretation with a smaller uncertainty of the image classifier, thereby increasing confidence of clinicians and laboratory staff when using RDTs, and creating opportunities for patient self-testing.


Subject(s)
COVID-19 Serological Testing , COVID-19/diagnosis , Machine Learning , Mobile Applications , SARS-CoV-2 , Humans
6.
J Proteome Res ; 20(2): 1434-1443, 2021 02 05.
Article in English | MEDLINE | ID: covidwho-1065788

ABSTRACT

Alternative methods to RT-PCR for SARS-CoV-2 detection are investigated to provide complementary data on viral proteins, increase the number of tests performed, or identify false positive/negative results. Here, we have developed a simple mass spectrometry assay for SARS-CoV-2 in nasopharyngeal swab samples using common laboratory reagents. The method employs high sensitivity and selectivity targeted mass spectrometry detection, monitoring nine constitutive peptides representative of the three main viral proteins and a straightforward pellet digestion protocol for convenient routine applications. Absolute quantification of N, M, and S proteins was achieved by addition of isotope-labeled versions of best peptides. Limit of detection, recovery, precision, and linearity were thoroughly evaluated in four representative viral transport media (VTM) containing distinct total protein content. The protocol was sensitive in all swab media with limit of detection determined at 2 × 103 pfu/mL, corresponding to as low as 30 pfu injected into the LC-MS/MS system. When tested on VTM-stored nasopharyngeal swab samples from positive and control patients, sensitivity was similar to or better than rapid immunoassay dipsticks, revealing a corresponding RT-PCR detection threshold at Ct ∼ 24. The study represents the first thorough evaluation of sensitivity and robustness of targeted mass spectrometry in nasal swabs, constituting a promising SARS-CoV-2 antigen assay for the first-line diagnosis of COVID-19 and compatible with the constraints of clinical settings. The raw files generated in this study can be found on PASSEL (Peptide Atlas) under data set identifier PASS01646.


Subject(s)
COVID-19/diagnosis , Chromatography, Liquid/methods , Nasopharynx/virology , SARS-CoV-2/metabolism , Spike Glycoprotein, Coronavirus/metabolism , Tandem Mass Spectrometry/methods , COVID-19/virology , Culture Media , Humans , Nucleocapsid/metabolism , Proteomics/methods , Reproducibility of Results , SARS-CoV-2/physiology , Sensitivity and Specificity , Specimen Handling/instrumentation , Specimen Handling/methods , Viral Proteins/metabolism
7.
J Clin Microbiol ; 59(2)2021 01 21.
Article in English | MEDLINE | ID: covidwho-1041793

ABSTRACT

Numerous severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) rapid serological tests have been developed, but their accuracy has usually been assessed using very few samples, and rigorous comparisons between these tests are scarce. In this study, we evaluated and compared 10 commercially available SARS-CoV-2 rapid serological tests using the STARD (Standards for Reporting of Diagnostic Accuracy Studies) methodology. Two hundred fifty serum samples from 159 PCR-confirmed SARS-CoV-2 patients (collected 0 to 32 days after the onset of symptoms) were tested with rapid serological tests. Control serum samples (n = 254) were retrieved from pre-coronavirus disease (COVID) periods from patients with other coronavirus infections (n = 11), positivity for rheumatoid factors (n = 3), IgG/IgM hyperglobulinemia (n = 9), malaria (n = 5), or no documented viral infection (n = 226). All samples were tested using rapid lateral flow immunoassays (LFIAs) from 10 manufacturers. Only four tests achieved ≥98% specificity, with the specificities ranging from 75.7% to 99.2%. The sensitivities varied by the day of sample collection after the onset of symptoms, from 31.7% to 55.4% (days 0 to 9), 65.9% to 92.9% (days 10 to 14), and 81.0% to 95.2% (>14 days). Only three of the tests evaluated met French health authorities' thresholds for SARS-CoV-2 serological tests (≥90% sensitivity and ≥98% specificity). Overall, the performances varied greatly between tests, with only one-third meeting acceptable specificity and sensitivity thresholds. Knowledge of the analytical performances of these tests will allow clinicians and, most importantly, laboratorians to use them with more confidence; could help determine the general population's immunological status; and may help diagnose some patients with false-negative real-time reverse transcription-PCR (RT-PCR) results.


Subject(s)
COVID-19 Serological Testing/methods , COVID-19/diagnosis , Diagnostic Tests, Routine/standards , SARS-CoV-2/isolation & purification , Antibodies, Viral/blood , COVID-19/blood , COVID-19/pathology , Diagnostic Tests, Routine/methods , Female , Humans , Immunoassay , Immunoglobulin G/blood , Immunoglobulin M/blood , Male , Middle Aged , Practice Guidelines as Topic , Retrospective Studies , SARS-CoV-2/immunology , Sensitivity and Specificity
8.
Am J Infect Control ; 48(12): 1533-1536, 2020 12.
Article in English | MEDLINE | ID: covidwho-813431

ABSTRACT

In the hospital department dedicated to COVID-19-patient, infection prevention and control measures were upgraded. Therefore, the cross-transmission of other micro-organisms was thought unlikely to occur. However, we report an outbreak of NDM-5-producing Escherichia. coli in a 12-beds ICU dedicated to COVID-19 patients. This outbreak involved 6 patients of which 5 were asymptomatic carriers and 1 was infected. Several findings might have contributed to cross-transmission including the multiple-bedroom configuration of the department, uncomplete compliance for standard and contact precautions, overwork due to the burden of the disease, lack of training of staff for the care of ICU-patients, and misuse of gloves. Furthermore, as infection prevention and control measures were thought to be applied, contact patients were not screened for eXDR carriage. Applying rigorously standard and contact precautions and performing screening in contact patients when indicated must be the rules in COVID-19 wards.


Subject(s)
COVID-19/microbiology , Carbapenem-Resistant Enterobacteriaceae , Coinfection/epidemiology , Cross Infection/epidemiology , Enterobacteriaceae Infections/epidemiology , SARS-CoV-2 , Adult , Aged , COVID-19/transmission , Coinfection/microbiology , Coinfection/transmission , Cross Infection/microbiology , Cross Infection/transmission , Disease Outbreaks , Enterobacteriaceae Infections/microbiology , Enterobacteriaceae Infections/transmission , Female , France/epidemiology , Humans , Intensive Care Units , Male , Middle Aged
9.
Emerg Microbes Infect ; 9(1): 2212-2221, 2020 Dec.
Article in English | MEDLINE | ID: covidwho-791927

ABSTRACT

Background: Several serological tests for SARS-CoV-2 have been developed or use, but most have only been validated on few samples, and none provide medical practitioners with an easy-to-use, self-contained, bedside test with high accuracy. Material and methods: Two-hundred fifty-six sera from 101 patients hospitalized with SARS-CoV-2 infection (positive RT-PCR) and 50 control sera were tested for IgM/IgG using the NG-Test IgM-IgG COVID all-in-one assay. The seroconversion dynamic was assessed by symptom onset and day of RT-PCR diagnosis. Results: Among the SARS-CoV-2 infected patients, positive IgG and/or IgM result was observed for 67.3% of patients (68/101), including 17 (16.8%) already positive at the day of RT-PCR, and 51 (50.5%) with observable seroconversion, and 32.7% (33/101) remained negative as subsequent sampling was not possible (patient discharge or death). The sensitivity increased with the delay between onset of symptoms and sampling, going from 29.1%, 78.2% and 86.5% for the time periods of 0-9-, 10-14- and >14-days after the onset of symptoms, respectively. Cumulative sensitivity, specificity, Positive Predictive Value and Negative Predictive Value were 97.0%, 100%, 100% and 96.2%, respectively 15-days after the onset of symptoms. No difference in seroconversion delay was observed regardless of whether patients received ventilation. Conclusions: The NG-test is a bedside serological assay that could serve as a complementary source of diagnostic information to RT-PCR and chest imaging. It may also be useful to monitor immunological status of medical and non-medical workers during the ongoing pandemic, and the general population after social distancing measures have eased.


Subject(s)
Antibodies, Viral/immunology , Betacoronavirus/immunology , Clinical Laboratory Techniques , Coronavirus Infections/diagnosis , Coronavirus Infections/immunology , Pneumonia, Viral/diagnosis , Pneumonia, Viral/immunology , Point-of-Care Testing , Serologic Tests/methods , Adult , Antibodies, Viral/blood , Betacoronavirus/genetics , COVID-19 , COVID-19 Testing , Case-Control Studies , Coronavirus Infections/virology , Female , Humans , Immunoglobulin G/blood , Immunoglobulin G/immunology , Immunoglobulin M/blood , Immunoglobulin M/immunology , Male , Middle Aged , Pandemics , Pneumonia, Viral/virology , Polymerase Chain Reaction , Reagent Strips , SARS-CoV-2 , Sensitivity and Specificity , Seroconversion , Serologic Tests/standards
SELECTION OF CITATIONS
SEARCH DETAIL